>UNE standards>UNE EN IEC 61869-11:2019 - Instrument transformers - Part 11: Additional requirements for low-power passive voltage transformers
in stockReleased: 2019-04-17
UNE EN IEC 61869-11:2019 - Instrument transformers - Part 11: Additional requirements for low-power passive voltage transformers

UNE EN IEC 61869-11:2019

Instrument transformers - Part 11: Additional requirements for low-power passive voltage transformers

Transformadores de medida. Parte 11: Requisitos adicionales para los transformadores de tensión pasivos de baja potencia.

Format
Availability
Price and currency
English PDF
Immediate download
Printable
117.76 USD
English Hardcopy
In stock
117.76 USD
Spanish PDF
Immediate download
Printable
117.76 USD
Spanish Hardcopy
In stock
117.76 USD
Standard number:UNE EN IEC 61869-11:2019
Pages:41
Released:2019-04-17
Status:Standard
Pages (Spanish):42
DESCRIPTION

UNE EN IEC 61869-11:2019

This part 11 of IEC 61869 is a product standard and covers only additional requirements for low-power passive voltage transformers (passive LPVT). The product standard for low-power passive voltage transformers is composed by the IEC 61869-1, in addition with IEC 61869-6 and this standard with specific requirements. This International Standard is applicable to newly manufactured low-power passive voltage transformers with analogue output having rated frequencies from 15 Hz to 100 Hz for use with electrical measuring instruments or electrical protective devices. This Standard covers low-power passive voltage transformers used for measurement or protection and low-power passive voltage transformers used for both measurement and protection. Low-power passive voltage transformers are based on the voltage divider principle. They can be built for example as resistive dividers, capacitive dividers or resistive-capacitive dividers. Low-power passive voltage transformers have analogue output only (for digital output or for technology using any kind of active electronic components refer to IEC 61869-7). Such low-power passive voltage transformers may include the secondary signal cable (transmitting cable). According to a general block diagram given in Figure 601 (IEC 61869-6), the low-power passive voltage transformers do not use an active primary converter (i.e. without any active electronic component); therefore, there is no need for primary power supply. Additionally, neither the secondary converter nor the secondary power supply is used. The general block diagram of a low-power passive voltage transformer is given in Figure 1101. The applied technology decides which part is necessary for the realization of a low-power passive voltage transformer, i.e. it is not necessary that transmitting cable or primary converter described in Figure 1101 are included in the low-power passive voltage transformer.