UNE EN ISO 10993-15:2024 - Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys (ISO 10993-15:2019)

UNE EN ISO 10993-15:2024

Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys (ISO 10993-15:2019)

Evaluación biológica de productos sanitarios. Parte 15: Identificación y cuantificación de los productos de degradación de metales y aleaciones. (ISO 10993-15:2019).

Format
Availability
Price and currency
English PDF
Immediate download
Printable
101.64 EUR
English Hardcopy
In stock
101.64 EUR
Spanish PDF
Immediate download
Printable
84.70 EUR
Spanish Hardcopy
In stock
84.70 EUR
Standard number:UNE EN ISO 10993-15:2024
Pages:27
Released:2024-01-17
Status:Standard
Pages (Spanish):29
DESCRIPTION

UNE EN ISO 10993-15:2024

This document provides guidance on general requirements for the design of tests for identifying and quantifying degradation products from final metallic medical devices or corresponding material samples finished as ready for clinical use. This document is applicable only to those degradation products generated by chemical alteration of the final metallic device in an in vitro accelerated degradation test. Because of the accelerated nature of these tests, the test results may not reflect the implant or material behavior in the body. The described chemical methodologies are a means to generate degradation products for further assessments. This document considers both materials designed to degrade in the body as well as materials that are not intended to degrade. This document is not applicable to degradation products induced by applied mechanical stress. Mechanically induced degradation, such as wear, can be covered in the appropriate product-specific standard. Where product-group standards provide applicable product-specific methodologies for the identification and quantification of degradation products, those standards should be considered. Because of the wide range of metallic materials used in medical devices, no specific analytical techniques are identified for quantifying the degradation products. The identification of trace elements (< 10 6 w/w) contained in the specific metal or alloy is not addressed in this part of ISO 10993, nor are specific requirements for acceptable levels of degradation products provided in this part of ISO 10993. This document does not address the biological activity of the degradation products; see instead the applicable clauses of ISO 10993-1 and ISO 10993-17.