UNE EN ISO 15883-7:2025 - Washer-disinfectors - Part 7: Requirements and tests for washer-disinfectors employing chemical disinfection for non-critical thermolabile medical devices and health care equipment (ISO 15883-7:2025)

UNE EN ISO 15883-7:2025

Washer-disinfectors - Part 7: Requirements and tests for washer-disinfectors employing chemical disinfection for non-critical thermolabile medical devices and health care equipment (ISO 15883-7:2025)

Lavadoras desinfectadoras. Parte 7: Requisitos y ensayos para las lavadoras desinfectadoras que utilizan desinfección química para los productos sanitarios termolábiles no críticos y para los equipos de asistencia sanitaria. (ISO 15883-7:2025).

Format
Availability
Price and currency
English PDF
Immediate download
Printable
155.29 USD
English Hardcopy
In stock
155.29 USD
Spanish PDF
Immediate download
Printable
129.41 USD
Spanish Hardcopy
In stock
129.41 USD
Standard number:UNE EN ISO 15883-7:2025
Pages:45
Released:2025-12-10
Status:Standard
Pages (Spanish):51
DESCRIPTION

UNE EN ISO 15883-7:2025

This document specifies the requirements for washer-disinfectors (WD) intended to be used for the cleaning and chemical disinfection, in a single operating cycle, of reusable items such as the following: a) bed frames; b) bedside tables; c) transport carts; d) containers; e) surgical tables; f) sterilization containers; g) surgical clogs; h) wheelchairs; i) aids for persons with disabilities. This document also specifies the performance requirements for the cleaning and disinfection of the WD and its components and accessories which are necessary in order to achieve the required performance. Devices identified within the scopes of ISO 15883-2, ISO 15883-3, ISO I5883-4, and ISO 15883-6 do not fall within the scope of this document. In addition, the methods are specified, as well as instrumentation and instructions required, for type testing, works testing, validation (installation, operation, and performance qualification on first installation), routine control, and monitoring, as well as requalifications required to be carried out periodically and after essential repairs. NOTE 1 WD corresponding to this document can also be used for cleaning and chemical disinfection of other thermolabile and reusable devices as recommended in the IFU for those devices. NOTE 2 The specified performance requirements of this document cannot ensure the inactivation or removal of the causative agent(s) (prion proteins) of transmissible spongiform encephalopathies.