PRICES include / exclude VAT
Homepage>ASTM Standards>27>27.060>27.060.10>ASTM D6448-16R22 - Standard Specification for Industrial Burner Fuels from Used Lubricating Oils
Released: 01.10.2022

ASTM D6448-16R22 - Standard Specification for Industrial Burner Fuels from Used Lubricating Oils

Standard Specification for Industrial Burner Fuels from Used Lubricating Oils

Format
Availability
Price and currency
English PDF
Immediate download
60.99 USD
English Hardcopy
In stock
60.99 USD
Standard number:D6448-16R22
Released:01.10.2022
Status:Active
Pages:6
Section:05.02
Keywords:burner fuels; fuel oils; furnace oils; petroleum and petroleum products; specifications; used oils; viscosity;
DESCRIPTION

1.1 This specification covers four grades of fuel oil made in whole or in part with hydrocarbon-based used or reprocessed lubricating oil or functional fluids, such as preservative and hydraulic fluids. The four grades of fuel are intended for use in various types of fuel-oil-burning industrial equipment under various climatic and operating conditions. These fuels are not intended for use in residential heaters, small commercial boilers, combustion engines, or marine applications,

1.1.1 Grades RFO4, RFO5L, RFO5H, and RFO6 are used lubricating oil blends, with or without distillate or residual fuel oil, or both, of increasing viscosity and are intended for use in industrial burners equipped to handle these types of recycled fuels.

Note 1: For information on the significance of the terminology and test methods used in this specification, see Appendix X1.

1.2 This specification is for use in contracts for the purchase of fuel oils derived from used lubricating oil and for the guidance of consumers of such fuels. This specification does not address the frequency with which any particular test must be run.

1.3 Nothing in this specification shall preclude observance of national or local regulations, which can be more restrictive. In some jurisdictions, used oil is considered a hazardous waste and fuels from used oil are required to meet certain criteria before use as a fuel.

Note 2: For United States federal requirements imposed on used oil generators, transporters and transfer facilities, reprocessors, marketers, and burners, see 40 CFR 279.

Note 3: The generation and dissipation of static electricity can create problems in the handling of distillate burner fuel oils. For more information on the subject, see Guide D4865.

1.4 The values stated in SI units are to be regarded as standard; non-SI units, when given, are for information only.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.