PRICES include / exclude VAT
Homepage>ASTM Standards>71>71.080>71.080.15>ASTM D7065-17 - Standard Test Method for Determination of Nonylphenol, Bisphenol A, <emph type="bdit" >p-tert</emph>-Octylphenol, Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters by Gas Chromatography Mass Spectrometry
Released: 15.12.2017

ASTM D7065-17 - Standard Test Method for Determination of Nonylphenol, Bisphenol A, <emph type="bdit" >p-tert</emph>-Octylphenol, Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters by Gas Chromatography Mass Spectrometry

Standard Test Method for Determination of Nonylphenol, Bisphenol A, <emph type="bdit" >p-tert</emph>-Octylphenol, Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters by Gas Chromatography Mass Spectrometry

Format
Availability
Price and currency
English PDF Redline
Immediate download
77.04 USD
English PDF
Immediate download
64.20 USD
English Hardcopy
In stock
64.20 USD
Standard number:D7065-17
Released:15.12.2017
Status:Active
Pages:14
Section:11.02
Keywords:bisphenol A; continuous liquid-liquid extraction; diethoxylate; ethoxylate; gas chromatography; mass spectrometry; monoethoxylate; nonylphenol; octylphenol; water;
DESCRIPTION

1.1 This test method covers determination of nonylphenol (NP), nonylphenol ethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), octylphenol (OP), and bisphenol A (BPA) that are partitioned into organic solvent, separated using gas chromatography and detected with mass selective detection. These compounds or isomer mixtures are qualitatively and quantitatively determined by this test method. This test method adheres to selected ion monitoring mass spectrometry but full scan mass spectrometry has also been shown to work well under these conditions. Either analysis may be used.

1.2 The method detection limit (MDL) and reporting limit (RL) for NP, NP1EO, NP2EO, OP, and BPA are listed in Table 1.

(A) MDL determined following the Code of Federal Regulations, 40 CFR Part 136, Appendix B.
(B) Lowest point of the reporting range is calculated from the LV1 concentration calibration standard in Table 4.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.