DESCRIPTION

1.1 This practice describes specified apparatus and procedures for collection of non-fibrous airborne metal nanoparticles generated during work activities.

1.2 Nanoparticle respiratory deposition (NRD) samplers are designed to follow a nanoparticulate matter (NPM) deposition curve based on the International Commission on Radiological Protection (ICRP) model for deposition of particles smaller than 300 nm (the minimum deposition for submicrometre particles) while removing the larger particles (1).2

1.3 This practice is applicable to personal and area sampling during work processes and situations where metal nanoparticles may be generated (for example, welding, smelting, shooting ranges).

1.4 This practice is intended for use by professionals experienced in the use of devices for occupational air sampling (such as cyclone samplers).

1.5 This practice is not applicable to the sampling of fibrous nanoparticles such as carbon nanotubes.

1.6 Detailed operating instructions are not provided owing to differences among various makes and models of suitable devices and instruments. The user is expected to follow specific instructions provided by the manufacturers of particular items of equipment. This practice does not address comparative accuracy of different devices nor the precision between instruments of the same make and model.

1.7 This practice contains notes that are explanatory and are not part of the mandatory requirements of the method.

1.8 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.