PRICES include / exclude VAT
Homepage>ASTM Standards>17>17.240>ASTM E1261-13R20 - Standard Practice for Calibration of Routine Dosimetry Systems for Radiation Processing
Released: 01.10.2020

ASTM E1261-13R20 - Standard Practice for Calibration of Routine Dosimetry Systems for Radiation Processing

Standard Practice for Calibration of Routine Dosimetry Systems for Radiation Processing

Format
Availability
Price and currency
English PDF
Immediate download
64.20 USD
English Hardcopy
In stock
64.20 USD
Standard number:E1261-13R20
Released:01.10.2020
Status:Active
Pages:19
Section:12.02
Keywords:absorbed dose; accredited laboratory; dosimeter; dosimetry system calibration; dosimetry system; electron beam; gamma radiation; ionizing radiation; measurement traceability; radiation processing; reference standard dosimetry system; routine dosimeter; transfer standard dosimetry system; Type I dosimeter; Type II dosimeter; X-ray; X-radiation;
DESCRIPTION

1.1 This practice specifies the requirements for calibrating routine dosimetry systems for use in radiation processing, including establishing measurement traceability and estimating uncertainty in the measured dose using the calibrated dosimetry system.

Note 1: Regulations or other directives exist in many countries that govern certain radiation processing applications such as sterilization of healthcare products and radiation processing of food requiring that absorbed-dose measurements be traceable to national or international standards (ISO 11137-1, Refs (1-3)2).

1.2 The absorbed-dose range covered is up to 1 MGy.

1.3 The radiation types covered are photons and electrons with energies from 80 keV to 25 MeV.

1.4 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM E2628 “Practice for Dosimetry in Radiation Processing” for the calibration of routine dosimetry systems. It is intended to be read in conjunction with ASTM E2628 and the relevant ASTM or ISO/ASTM standard practice for the dosimetry system being calibrated referenced in Section 2.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.