PRICES include / exclude VAT
Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.060 Electrical wires and cables>29.060.20 Cables>BS 7769-2.2:1997 Electric cables. Calculation of the current rating. Thermal resistance A method for calculating reduction factors for groups of cables in free air, protected from solar radiation
immediate downloadReleased: 1997-02-15
BS 7769-2.2:1997 Electric cables. Calculation of the current rating. Thermal resistance A method for calculating reduction factors for groups of cables in free air, protected from solar radiation

BS 7769-2.2:1997

Electric cables. Calculation of the current rating. Thermal resistance A method for calculating reduction factors for groups of cables in free air, protected from solar radiation

Format
Availability
Price and currency
English Secure PDF
Immediate download
163.80 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
16.38 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
49.14 USD
English Hardcopy
In stock
163.80 USD
Standard number:BS 7769-2.2:1997
Pages:12
Released:1997-02-15
ISBN:0 580 26923 X
Status:Standard
DESCRIPTION

BS 7769-2.2:1997


This standard BS 7769-2.2:1997 Electric cables. Calculation of the current rating. Thermal resistance is classified in these ICS categories:
  • 29.060.20 Cables

The method described in this International Standard is applicable to any type of cable and group running horizontally, provided that the cables are of equal diameter and emit equal losses.

Information is provided on the reduction in permissible current when cables are mounted adjacent to each other. It is limited to the following cases:

  1. a maximum of nine cables in a square formation, see Figure 1, and

  2. a maximum of six circuits each comprised of three cables mounted in trefoil, with up to three circuits placed side by side or two circuits placed one above the other, see Figure 2.

Caution is advised where air flow around the cables may be restricted by proximity to neighbouring objects.

NOTE Further work is to be done to extend and refine the data and to include the effect of dielectric loss.

Information is provided for the following situations:

  • Where a rating for one cable or circuit assumed to be isolated exists, group reduction factors can be derived for the same type of cable, see 4.1.

  • Where previously calculated ratings are not available, the data provided can be used to calculate permissible currents for groups of cables, using the formulae in parts 1 and 2, see 4.2.

  • Where adequate clearances can be provided between cables to avoid a reduction in permissible current, see clause 5.


Applicable to any type of cable and group, running horizontally. Information is provided on the reduction in permissible current when cables are mounted adjacent to each other.