Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.060 Electrical wires and cables>29.060.20 Cables>BS 7870-8.6:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors
immediate downloadReleased: 2003-06-16
BS 7870-8.6:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors

BS 7870-8.6:2003

LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and non-halogenated sheathed multipair cable with copper conductors

Format
Availability
Price and currency
English Secure PDF
Immediate download
270.40 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
27.04 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
81.12 USD
English Hardcopy
In stock
270.40 USD
Standard number:BS 7870-8.6:2003
Pages:28
Released:2003-06-16
ISBN:0 580 37572 2
Status:Standard
DESCRIPTION

BS 7870-8.6:2003


This standard BS 7870-8.6:2003 LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground is classified in these ICS categories:
  • 29.060.20 Cables

This section of BS 7870 specifies requirements for the construction, dimensions and mechanical and physical properties of multipair cables with halogen-free insulation and sheaths, having reduced fire propagation performance and low emission of smoke when affected by fire.

It specifies requirements for multipair cables (up to 200-pair) with copper conductors, a collective screen and armouring consisting of a single layer of steel wires or a double layer of steel tapes.

It specifies requirements for both Type 1 and Type 2 cables, which are defined as follows:

  • Type 1: cable designed for the installation and operating conditions prevailing in a conventional fossil fuelled power station or equivalent location;
  • Type 2: cable designed for the installation and operating conditions prevailing in a PWR power station, but excluding location in or around the containment area.

The requirements specified in this section of BS 7870 are applicable to both Type 1 and Type 2 cables unless otherwise indicated.

This section of BS 7870 is applicable to cables for use in and around power stations and other installations having similar cable densities.

NOTE A “guide to use” is given in Annex A.