PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.320 Alarm and warning systems>BS EN 50194-2:2019 Electrical apparatus for the detection of combustible gases in domestic premises Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises. Additional test methods and performance requirements
immediate downloadReleased: 2019-06-14
BS EN 50194-2:2019 Electrical apparatus for the detection of combustible gases in domestic premises Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises. Additional test methods and performance requirements

BS EN 50194-2:2019

Electrical apparatus for the detection of combustible gases in domestic premises Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises. Additional test methods and performance requirements

Format
Availability
Price and currency
English Secure PDF
Immediate download
195.00 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.50 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
58.50 USD
English Hardcopy
In stock
195.00 USD
Standard number:BS EN 50194-2:2019
Pages:22
Released:2019-06-14
ISBN:978 0 539 00019 1
Status:Standard
DESCRIPTION

BS EN 50194-2:2019


This standard BS EN 50194-2:2019 Electrical apparatus for the detection of combustible gases in domestic premises is classified in these ICS categories:
  • 13.320 Alarm and warning systems

This Clause of EN 50194‑1 is replaced by:

This document specifies test methods and performance requirements for electrical apparatus for the detection of combustible gases designed for continuous operation in a fixed installation in recreational vehicles and similar premises.

NOTE 1

For caravan holiday homes EN 50194‑1 applies.

This document specifies apparatus designed to operate in the event of an escape of liquefied petroleum gas (LPG) and/or petrol (gasoline) vapour and to provide a visual and audible alarm and an executive action in the form of an output signal that can actuate directly or indirectly a shut-off device and/or other ancillary device ( Type A of EN 50194‑1 ).

The document excludes apparatus for the detection of toxic gases such as carbon monoxide (see EN 50291 ).

Apparatus complying with this document is not considered suitable for industrial or commercial installations for which EN 60079‑29‑1 apply.

NOTE 2

Apparatus tested in accordance with EN 60079‑29‑1 will not necessarily comply with this standard.