PRICES include / exclude VAT
Homepage>BS Standards>19 TESTING>19.120 Particle size analysis. Sieving>BS ISO 21501-1:2009 Determination of particle size distribution. Single particle light interaction methods Light scattering aerosol spectrometer
immediate downloadReleased: 2009-06-30
BS ISO 21501-1:2009 Determination of particle size distribution. Single particle light interaction methods Light scattering aerosol spectrometer

BS ISO 21501-1:2009

Determination of particle size distribution. Single particle light interaction methods Light scattering aerosol spectrometer

Format
Availability
Price and currency
English Secure PDF
Immediate download
317.20 USD
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
31.72 USD
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
95.16 USD
English Hardcopy
In stock
317.20 USD
Standard number:BS ISO 21501-1:2009
Pages:38
Released:2009-06-30
ISBN:978 0 580 59623 0
Status:Standard
DESCRIPTION

BS ISO 21501-1:2009


This standard BS ISO 21501-1:2009 Determination of particle size distribution. Single particle light interaction methods is classified in these ICS categories:
  • 19.120 Particle size analysis. Sieving

This part of ISO 21501 specifies characteristics of a light scattering aerosol spectrometer (LSAS) which is used for measuring the size, number concentration and number/size distribution of particles suspended in a gas. The light scattering technique described in this part of ISO 21501 is based upon single particle measurements. The size range of particles measured by this method is between approximately 0,06 µm to 45 µm in diameter.

Instruments that conform to this part pf ISO 21501 are used for the determination of the particle size distribution and particle number concentration at relatively high concentrations of up to 1011 particles/m3.

Application fields include:

  • characterization of metered dose inhalers (MDI), dry powder inhalers (DPI) and nebulizers in pharmacy;

  • production control of active agents;

  • cut-off determination: impactors, cyclones and impingers;

  • atmospheric aerosols: bio-aerosols, stables/composting facilities, nebulized droplets, measurements in street tunnels;

  • fractional separation efficiency determination of filters.

For the above-mentioned applications, aerosol spectrometers should determine the particle size distribution, particle number concentration, size resolution and sizing accuracy as accurately as possible. These aerosol spectrometers are not suitable for the classification of clean rooms.