PRICES include / exclude VAT
>CSN EN 303-5 - Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking
Sponsored link
download between 0-24 hoursReleased: 2012
CSN EN 303-5 - Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking

CSN EN 303-5

Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking

CURRENCY
LANGUAGE
English
Number of Standard:CSN EN 303-5
Category:075303
Released:2012
Language:English
DESCRIPTION

EN 303-5


EN 303-5 Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking - 1.1 General This European Standard applies to heating boilers including safety devices up to a nominal heat output of 500 kW which are designed for the burning of solid fuels only and are operated according to the instructions of the boiler manufacturer. This European Standard deals with significant hazards, hazardous situations and events relevant to heating boilers used as intended and under the conditions foreseen by the manufacturer (see Clause 4). The boilers may operate under natural draught or forced draught. The stoking may work manually or automatically. NOTE This European Standard deals with boilers which are both within and outside of the scope of the Machinery Directive 2006/42/EC. This European Standard contains requirements and test methods for safety, combustion quality, operating characteristics, marking and maintenance of heating boilers. It also covers all external equipment that influences the safety systems (e.g. back burning safety device, integral fuel hopper). This European Standard covers only boilers that include burners as a unit. The standard applies to the combination of a boiler body with a solid fuel burner according to EN 15270 as a unit only when the whole unit is tested in accordance with this European Standard. Heating boilers in accordance with this European Standard are designed for central heating installations where the heat carrier is water and the maximum allowable temperature is 110 °C, and which can operate at a maximum allowable operating pressure of 6 bars. For heating boilers with a built-in or attached water heater (storage or continuous flow heater), this European Standard only applies to those parts of the water heater which are necessarily subject to the operating conditions of the heating boiler (heating part). This European Standard does not apply to: - heating boilers and other heating appliances which are also designed for the direct heating of the place of installation; - cooking appliances; - the design and construction of external fuel storage and transportation devices prior to the safety devices of the boiler; - room sealed applications; - condensing boilers. This European Standard specifies the necessary terminology for solid fuel heating boilers, the control and safety related requirements, the design requirements, the technical heating requirements (taking into account the environmental requirements) and testing, as well as the marking requirements. This European Standard is not applicable to heating boilers which are tested before the date of its publication as an EN (European Standard). (...)

Original English text of CSN EN Standard.
The price of the Standard included all amendments and correcturs.
Related products
download between 0-24 hours
Released: 2006
CSN EN 15036-1
Heating boilers - Test regulations for airborne noise emissions from heat generators - Part 1: Airborne noise emissions from heat generators
LANGUAGE
English
download between 0-24 hours
Released: 2006
CSN EN 15036-2
Heating boilers - Test regulations for airborne noise emissions from heat generators - Part 2: Flue gas noise emissions at the outlet of the heat generator
LANGUAGE
English
download between 0-24 hours
Released: 2006
CSN EN 15034
Heating boilers - Condensing heating boilers for fuel oil
LANGUAGE
English
download between 0-24 hours
Released: 2007
CSN EN 15332
Heating boilers - Energy assessment of hot water storage systems
LANGUAGE
English
download between 0-24 hours
Released: 1999
CSN EN 303-1
Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking
LANGUAGE
English
download between 0-24 hours
Released: 1998
CSN EN 303-2
Heating boilers - Part 2: Heating boilers with forced draught burners - Special requirements for boilers with atomizing oil burners
LANGUAGE
English
download between 0-24 hours
Released: 1998
CSN EN 303-3
Heating boilers - Part 3: Gas-fired central heating boilers - Assembly comprising a boiler body and a forced draught burner
LANGUAGE
English
download between 0-24 hours
Released: 1999
CSN EN 303-4
Heating boilers - Part 4: Heating boilers with forced draught burners - Special requirements for boilers with forced draught oil burners with outputs up to 70 kW and maximum operating pressure of 3 bar - Terminology, special requirements, testing and marking
LANGUAGE
English
download between 0-24 hours
Released: 2000
CSN EN 303-6
Heating boilers - Part 6: Heating boilers with forced draught burners - Specific requirements for the domestic hot water operatin of combination boilers with atomizing oil burners of nominal heat input not exceeding 70 kW
LANGUAGE
English
download between 0-24 hours
Released: 2006
CSN EN 303-7
Heating boilers - Part 7: Gas-fired central heating boilers equipped with a forced draught burner of nominal heat output not exceeding 1 000 kW
LANGUAGE
English
download between 0-24 hours
Released: 1992
CSN EN 304
Heating boilers. Test Code for heating boilers for atomizing oil burners
LANGUAGE
English
download between 0-24 hours
Released: 2006
CSN EN 15035
Heating boilers - Special requirements for oil fired room sealed units up to 70 kW
LANGUAGE
English
download between 0-24 hours
Released: 2008
CSN EN 14394+A1
Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C
LANGUAGE
English
download between 0-24 hours
Released: 2008
CSN EN 15456
Heating boilers - Electrical power consumption for heat generators - System boundaries - Measurements
LANGUAGE
English
download between 0-24 hours
Released: 1999
CSN EN 656
Gas-fired central heating boilers - Type B boilers of nominal heat input exceeding 70 kW but not exceeding 300 kW
LANGUAGE
English
download between 0-24 hours
Released: 2006
CSN EN 13836
Gas fired central heating boilers - Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1 000 kW
LANGUAGE
English
download between 0-24 hours
Released: 2015
CSN EN 15502-1+A1
Gas-fired heating boilers - Part 1: General requirements and tests
LANGUAGE
English
download between 0-24 hours
Released: 2014
CSN EN 15502-2-2
Gas-fired central heating boilers - Part 2-2: Specific standard for type B1 appliances
LANGUAGE
English
download between 0-24 hours
Released: 2016
CSN EN 15502-2-1+A1
Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW
LANGUAGE
English