PRICES include / exclude VAT
Homepage>CSN Standards>83 ENVIRONMENT PROTECTION, WORKING AND PERSONAL PROTECTION, SAFETY OF MACHINE EQUIPMENT AND ERGONOMICS>8335 Ergonomics>CSN EN ISO 7933 - Ergonomics of the thermal environment - Analytical determination and interpretation of heat stress using calculation of the predicted heat strain
Released: 01.01.2024
CSN EN ISO 7933 - Ergonomics of the thermal environment - Analytical determination and interpretation of heat stress using calculation of the predicted heat strain

CSN EN ISO 7933

Ergonomics of the thermal environment - Analytical determination and interpretation of heat stress using calculation of the predicted heat strain

Format
Availability
Price and currency
English Hardcopy
In stock
93.33 USD
FREE Shipping
Number of Standard:CSN EN ISO 7933
Category:833562
Pages:44
Released:01.01.2024
Catalog number:518189
DESCRIPTION

CSN EN ISO 7933

CSN EN ISO 7933 This document describes a model [the predicted heat strain (PHS) model] for the analytical determination and interpretation of the thermal stress (in terms of water loss and rectal temperature) experienced by an average person in a hot environment and determines the maximum allowable exposure times within which the physiological strain is acceptable for 95 % of the exposed population (the maximum tolerable rectal temperature and the maximum tolerable water loss are not exceeded by 95 % of the exposed people). The various terms used in this prediction model and, in particular, in the heat balance, show the influence of the different physical parameters of the environment on the thermal stress experienced by the average person. In this way, this document makes it possible to determine which parameter or group of parameters can be changed, and to what extent, in order to reduce the risk of excessive physiological strain. In its present form, this method of assessment is not applicable to cases where special protective clothing (e.g. fully reflective clothing, active cooling and ventilation, impermeable coveralls) is worn. This document does not predict the physiological response of an individual person, but only considers average persons in good health and fit for the work they perform. It is therefore intended to be used by, among others, ergonomists and industrial hygienists, as the outcomes can require expert interpretations. Recommendations about how and when to use this model are given in ISO 8025.
Original English text of CSN EN Standard.
The price of the Standard included all amendments and correcturs.