PRICES include / exclude VAT
Homepage>IEC Standards>IEC 61010-031:2015+AMD1:2018 CSV - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
Sponsored link
Not available online - contact us!
download between 0-24 hoursReleased: 2018-05-29
IEC 61010-031:2015+AMD1:2018 CSV - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement

IEC 61010-031:2015+AMD1:2018 CSV

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement

Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 031: Exigences de sécurité pour sondes équipées portatives et manipulées à la main pour mesurage et essais électriques

CURRENCY
611.11 USD
Standard number:IEC 61010-031:2015+AMD1:2018 CSV
Released:2018-05-29
Language:English
DESCRIPTION

IEC 61010-031:2015+AMD1:2018 CSV

IEC 61010-031:2015+A1:2018 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. It has the status of a group safety publication in accordance with IEC GUIDE 104. IEC 61010-031 is a stand-alone standard. This second edition cancels and replaces the first edition published in 2002 and Amendment 1:2008. This edition constitutes a technical revision. This edition includes the following significant changes from the first edition, as well as numerous other changes: a) Voltages above the levels of 30 V r.m.s., 42,4 V peak, or 60 V d.c. are deemed to be HAZARDOUS LIVE instead of 33 V r.m.s., 46,7 V peak, or 70 V d.c. b) Servicing is now included within the scope. c) Extended environmental conditions are included within the scope. d) New terms have been defined. e) Tests for REASONABLY FORESEEABLE MISUSE have been added, in particular for fuses. f) Additional instruction requirements for probe assembly operation have been specified. g) Limit values for ACCESSIBLE parts and for measurement of voltage and touch current have been modified. h) SPACINGS requirements for mating of CONNECTORS have been modified. i) PROBE TIPS and SPRING-LOADED CLIPS requirements have been modified. The PROTECTIVE FINGERGUARD replace the BARRIER with new requirements. j) Insulation requirements (6.5) and test procedures (6.6.5) have been rewritten and aligned when relevant with Part 1. Specific requirements have been added for solid insulation and thin-film insulation. k) The terminology for MEASUREMENT CATEGORY I has been replaced with the designation "not RATED for measurements within MEASUREMENT CATEGORIES II, III, or IV". l) The flexing/pull test (6.7.4.3) has been partially rewritten. m) Surface temperature limits (Clause 10) have been modified to conform to the limits of IEC Guide 117. n) Requirements for resistance of PROBE WIRES to mechanical stresses have been added in Clause 12 and a new Annex D. o) Requirements have been added regarding the prevention of HAZARD from arc flash and short-circuits for SPRING-LOADED CLIPS. p) A new informative Annex E defines the dimension of the 4 mm banana CONNECTORS. This consolidated version consists of the second edition (2015) and its amendment 1 (2018). Therefore, no need to order amendment in addition to this publication.