VDA 19.1 edition 2026
Inspection of Technical Cleanliness >Particulate Contamination of Functionally Relevant Automotive Components / 3rd Revised Edition, 2026
Band 19 Teil 1 Prüfung der Technischen Sauberkeit. Partikelverunreinigung funktionsrelevanter Automobilteile, 3., überarbeitete Auflage, Februar 2026
English version Coming soon - available in April 2026 - PRE ORDER NOW
| Standard number: | VDA 19.1 edition 2026 |
| Released: | 2026 |
| Edition: | 3rd |
| Pages: | 297 |
VDA 19.1
Purchase This volume 19.1 today and receive it within 2 days in EU and 3-5 days worldwide with UPS Service. See more in our delivery charges site.
Don't forget order also VDA 19.2 Technical cleanliness in assembly - Environment, Logistics, Personnel and Assembly Equipment
Description English:
Since the first edition of VDA Volume 19 was published in 2004, technical cleanliness has become a key quality characteristic in the automotive industry, which has necessitated the establishment of a number of laboratories and new role profiles, as well as several revisions of the guideline. With the introduction of VDA 19.1 (Analysis) and VDA 19.2 (Assembly), this topic has been further explored and standardized across the industry.
Due to continuous technological progress, the widespread application of the guidelines and the experience gained, a comprehensive revision of VDA Volume 19.1 has finally become necessary.
The main objectives of the revision (February 2023 to May 2025) were:
– Incorporation of new dry extraction methods and new analytical techniques
– Maintaining easily comparable standard analyses while enabling the development of problem-specific, custom tests within defined requirements
– More precise description of particle testing < 50 µm
– Development of standard SEM/EDX analysis with uniform material classes
– Numerous optimizations and improvements in test procedure development and adjustment of initial parameters based on many years of experience in purity testing laboratories
The basic methods and procedures for testing component purity, which were already included in the first and second editions, have proven to be highly effective and have been fully retained in the revision in a more precise and expanded form.
Thanks to the expansion and clarification of the revised third edition of VDA 19.1, this set of rules can not only be used for the design, execution and documentation of cleanliness tests in the laboratory, but is also suitable for other fields such as quality assurance, design and development or supplier management as a quick introduction to the topic.
All other VDA standards and Volumes can found here.
VDA 19.1 and other VDA Standards are not available in PDF format
Technical cleanliness in assembly - Environment, Logistics, Personnel and Assembly Equipment
Process Audit
Decorative Surfaces of external fittings and functional parts in the internal and externals of automobiles